banner_wyszukiwarka(4).jpg

Kitchen fan cookvent IKB-315 2300m3 / h

The Symbol : 92572

Cookvent kitchen fan IKB-315 2300m3/h

The Availability Of : Duża dostępność

: 3790.00

: 3790.00

Inne modele:
opak
Phone orde SMS: +48606376838

Shipping within : 24 hours
EAN :
5905679892572

Cooker hood duct fan IKB 315

Design  - Direct drive centrifugal fan. The enclosure is made of galvanized sheet metal, acoustically and thermally insulated with 50mm thick mineral wool. The rotor with the blades inclined backwards, made of galvanized sheet metal. The enclosure has a hinged inspection flap, allowing for convenient servicing and cleaning of the fan.

Electric  motor - Asynchronous single-phase 230V, 50Hz without the possibility of changing the rotational speed or three-phase 400V, 50Hz adapted to be regulated by a frequency converter. IP 55 protection, Insulation class F.

Application  - IKB fans are designed for both domestic and commercial kitchen extractors: bars, canteens, pubs, restaurants, schools, hospitals.

Operating  temperature - The fan is designed to pump air with a temperature not exceeding 120 °C.

SPECIFICATIONS:

image

DIMENSIONS  :

image
Parameters :
Brand:
Havaco
Energy efficiency class:
A
Hole diameter:
315 mm
Material:
galvanized sheet
Packaging Condition:
oryginalne
Status:
New

Safety Information

General Safety Rules for Mechanical Fans for Building Ventilation

Mechanical fans are a key component of mechanical ventilation systems in residential, commercial and industrial buildings. Their correct installation, operation and maintenance are crucial for the safety of users, the efficiency of the system and the durability of the device.

Principles of safe use and installation

Installation by qualified personnel only
A mechanical fan should be installed by persons with appropriate electrical qualifications and experience in the installation of mechanical ventilation systems.

Correct Mounting Location

The device should be installed in accordance with the installation design and manufacturer's documentation.

Keep a safe distance from heat sources, fire, gas installations and flammable materials.

Safe electrical connection

The electrical installation must be carried out in accordance with the applicable standards and manufacturer's requirements.

The fan should be connected to a properly protected electrical circuit with proper grounding.

Any service or installation work should be performed with the power supply disconnected.

Protection against moisture and dust

Use fans for their intended purpose – wet room models must have an appropriate IP rating.

Do not install fans where there is a risk of water damage, unless they have been designed to do so.

Proper fixation of the device

The device must be mounted stably to prevent vibration, noise and possible mechanical damage.

In the case of ceiling or roof fans, additional vibration protection must be used.

Ensuring free air flow

Do not obstruct fan inlets or outlets.

Regularly check the patency of the ventilation ducts to avoid overloading the motor.

Potential risks

Electric shock – resulting from improper connection, damaged wires or lack of grounding.

Engine overheating – caused by a lack of obstruction of ventilation ducts or a blockage of the rotor.

Risk of fire – when the fan is installed near flammable materials or in unsuitable environments.

Noise and vibration – incorrect installation can lead to excessive noise and damage to the building structure.

Decrease in air quality – an incorrectly selected fan can result in insufficient air exchange, which negatively affects the health of users.

Maintenance and inspections

Regularly clean the fan of dust, dust, and other debris to maintain its performance.

Check the condition of electrical cables, connections and the rotor.

Perform periodic technical inspections in accordance with the manufacturer's recommendations.

If abnormalities are detected, such as excessive noise, vibrations, burning smell or problems with the operation of the device – disconnect the power supply and contact an authorized service center.

Summary

Mechanical fans are reliable devices that ensure proper air circulation in buildings, but they require proper installation and operation.
Compliance with the above safety rules minimizes the risk of failure, increases the efficiency of the ventilation system and extends the life of the device.

Manufacturer details

Havaco
Działkowa 121A
02-234 Warszawa
Poland

606376838
info@wentec.pl

There is currently no comments or ratings for this product.
Ask a question

Zobacz co o nas mówią klienci